This European standard specifies requirements for rooflights made of plastic materials with and without upstands. These rooflights serve the purpose of providing natural daylight to interior of buildings and also ventilating interior spaces by the means of opening devices.
EN 1873 applies to rooflights with square, rectangular or circular shape up to a diameter of 2.5 metres or an opening width of not larger than 3 metres in roof pitches up to 25 degrees. It does not cover rooflights which contribute to the load bearing or stiffness of the roof itself. The standard applies to rooflights with or without upstands where they are provided by a single manufacturer and are purchased in a single purchase.
The exception to the above is where the rooflight is used for smoke and heat ventilation and this is covered by European Standard EN12101-2. Whitesales Em-Vent Smoke Ventilators fully comply with EN12101-2.
This standard does not include calculation with regard to construction, design requirements and installation techniques.
Performance Criteria
The European norm 1873 tests criteria in the following areas:
Testing
Some or all of the above criteria are tested in accordance with the guidelines set out in EN1873 and the manufacturer has to declare the test results in a Declaration of Performance (DoP).
Labelling
The products need to be labelled in accordance with CE Directive. This labelling can be on the packaging or the product itself and set out as specified by this European standard. For further information regarding EN1873 please contact Whitesales on 01483 271371 or sales@whitesales.co.uk.
A copy of our DoP can be downloaded here.
Because Smoke Ventilators are Life-saving devices they classify as Level 1 under CE EN120101-2 which stringently regulates the manufacture and sale of these products. The following is an overview of the requirements:
The products need to pass six stringent performance tests.
These include:
They need to be tested and certified independently.
All the above tests must be certified by an independent test body in order for manufacturers to produce a genuine Declaration of Performance (DoP) certificate.
The manufacturer and their processes have to have an independent annual audit.
This ensures consistency, with strict monitoring, recording and reporting of criteria known as Factory Production Control (FPC)
The products must have a genuine Declaration of Performance (DoP) Certificate.
The products must be CE certified as a complete unit, not as components.
CE 12101-2 stipulates the labelling of Smoke Vents must show:
It is very important that when sourcing or specifying a smoke vent that fully compliant products are used. For further information, guidance and assistance contact Whitesales on 01483 271371 or sales@whitesales.co.uk.